[COVID-19] PLASMA STERILIZER (HPS-50)
Zoom
[COVID-19] PLASMA STERILIZER (HPS-50)
Recommended for small and medium hospitals. Suitable to sterilize long surgical instruments. Compact design maximizing usability and convenience.

Product : Plasma Sterilizers (Low Temperature Plasma Sterilizers)
Manufacturer : Healthwell Medical, Inc.
Manufacturer Country : KOREA



Details

This product generate vacuum plasma inside the sterilization chamber to add Hydrogen Peroxide gas, which will decompose into OH radicals. These OH radicals kill microorganisms on the medical instruments which are heat and moisture sensitive. After sterilization, only water and oxygen will be left inside the sterilization chamber. And you can use the instruments immediately once the sterilization process is completed. Unlikely other sterilization technologies using harmful gases, a long process of removal of residual gas is not necessary.

Ideal for small medical institutions such as dentistry, ophthalmology, otolaryngology, and veterinary hospitals Designed to ensure user convenience and space efficiency with or without exclusive cart option.

1. 1. Easy to use
 You can start/cancel/control the sterilization process by simply pressing the key buttons.
 The selected sterilization cycle will be progressed automatically and you can monito 
 relevant information such as sterilization conditions, progress status, error messages from the display.

2. Automatic notification system for regular maintenance
  This product automatically notifies the replacement period for consumables such as pump oil,
  oil mist trap and air filter. It displays an error message to replace the consumable once it
  reaches 250 cycles. If the consumable is not replaced until it reaches 300 cycles,
  it will stop operation to prevent further equipment failure.

3. Built-in self-test
  When a malfunction occurs during operation, an error code is displayed by built-in self-test and 
  the running cycle is terminated automatically for safety.

4. Validation of Sterilization of HPS-30,50
 A PCD(Process Challenge Device) in accordance with EU standards(EN 867-5) is used for
 the validation sterilization of a dead-end lumen at the most difficult positions inside of the 
 sterilization load.
 Test mode : Special Mode(Lumen Mode)
 Lumen Size : HPS-30,50 (1∅×1,000mm(L), Teflon)



Specifications

Sterilizing Agent : Hydrogen Peroxide, 1Cycle/Cartridge
Total Cycle Time : Smart Mode : 40min                  
                         Standard Mode : 48min                 
                         Special Mode : 56min
Cycle Temperature : 45℃~60℃
SAL(Sterility Assurance Level) : 10⎺⁶ (Bacillus)
By-products : Oxygen and vapor water only
Chamber : Shape : Rectangular
              Material : Aluminum          
              Volume : Total : 50L
Dimensions : Overall : 594×525×890(W×H×D)mm            
                  Chamber : 338×236×660(W×H×D)mm
Weight : 110kg
Control : 32bit Micro Processor
Cycle Information : 2.7” (OLED) Display, Printer
Electrical : AC 220-230V~, 50Hz, Max 3.0kw
Installation Requirements : Front : 100cm                      
                                   Rear, Left side, Right side : 5cm                   
                                   Placement : Built-in wheels provide mobility(Option Cart)
Room Conditions : Use Environment : 10~40℃, 30~75%RH                  
                          Installation Environment : -20~60℃, 0~95%RH
Printer : Built-in Thermal Printer(Brief Mode / Detail Mode)         
           Cycle Parameters(Temp, Pressure, Time, Daily&Total Cycle, etc)
Cart(Option) : 613×880×850(W×H×D)mm


Consumables

● Sterilant Cartridges
   (Hydrogen Peroxide 50%)
   1 cartridge/cycle
● Packing
   Tyvek Pouch
   Non-Woven Sheet
   Impulse Sealer
● Maintenance*
    Vacuum Oil
    Oil Mist Trap

*Recommend to be changed every 250 cycles. However, the number of cycles can vary according to
daily practices of users in terms of sterilization loads(types, quantity, moisture content) and frequency
of sterilization and etc.

● Sterilization Monitoring
    CI(Chemical Indicator) : to monitor if the sterilization loads are exposed to H2O2 by a color change.
    BI(Biological Indicator) : to monitor if the sterilization is successful by an incubation of bacillus.
● Exclusive Cart(Option)
    HPS-50 : 613×880×850(W×H×D)mm

 