ENGLISH>
KOREAN

[COVID-19] PLASMA STERILIZER (HPS-30)
[COVID-19] PLASMA STERILIZER (HPS-30)
COMPANY PRODUCTS Data Center CUSTOMER SUPPORT
▷ COVID-19
TRAINING MANIKINSTRETCHER & SPLINTDEFIBRILLATOR▷ COVID-19MES : RestraintMES : Military equipmentMES : DMAT equipmentMES : Bags & Cases
[COVID-19] PLASMA STERILIZER (HPS-30)
Zoom
[COVID-19] PLASMA STERILIZER (HPS-30)
Recommended for small clinics including dental clinics. Compact design maximizing usability and convenience.

Product : Plasma Sterilizers (Low Temperature Plasma Sterilizers)
Manufacturer : Healthwell Medical, Inc.
Manufacturer Country : KOREA

Details
 

This product generate vacuum plasma inside the sterilization chamber to add Hydrogen Peroxide gas, which will decompose into OH radicals. These OH radicals kill microorganisms on the medical instruments which are heat and moisture sensitive. After sterilization, only water and oxygen will be left inside the sterilization chamber. And you can use the instruments immediately once the sterilization process is completed. Unlikely other sterilization technologies using harmful gases, a long process of removal of residual gas is not necessary.

Ideal for small medical institutions such as dentistry, ophthalmology, otolaryngology, and veterinary hospitals Designed to ensure user convenience and space efficiency with or without exclusive cart option.


 

1. Easy to use
 You can start/cancel/control the sterilization process by simply pressing the key buttons. The selected 
 sterilization cycle will be progressed automatically and you can monito relevant information such as
 sterilization conditions, progress status, error messages from the display.


2. Automatic notification system for regular maintenance
 This product automatically notifies the replacement period for consumables such as pump oil, oil mist
 trap  and air filter. It displays an error message to replace the consumable once it reaches 250 cycles.
 If the consumable is not replaced until it reaches 300 cycles, it will stop operation to prevent further
 equipment failure.


3. Built-in self-test
 When a malfunction occurs during operation, an error code is displayed by built-in self-test and
 the running cycle is terminated automatically for safety.


4. Validation of Sterilization of HPS-30,50
 A PCD(Process Challenge Device) in accordance with EU standards(EN 867-5) is used for
 the validation  of sterilization of a dead-end lumen at the most difficult positions inside of
 the sterilization load.

­ -Test mode : Special Mode(Lumen Mode)

 -Lumen Size : HPS-30,50 (1∅×1,000mm(L), Teflon)



Specifications

Sterilizing Agent : Hydrogen Peroxide, 1Cycle/Cartridge
Total Cycle Time : Smart Mode : 40min
                         Standard Mode : 48min
                         Special Mode : 56min
Cycle Temperature : 45℃~60℃
SAL(Sterility Assurance Level) : 10⎺⁶ (Bacillus)
By-products : Oxygen and vapor water only
Chamber : Shape : Rectangular
                          Material : Aluminum
                          Volume : Total : 30L
Dimensions : Overall : 594×525×605(W×H×D)mm
                  Chamber : 340×240×395(W×H×D)mm
Weight : 90kg
Control : 32bit Micro Processor
Cycle Information : 2.7” (OLED) Display, Printer
Electrical : AC 220-230V~, 50/60Hz, Max 2.7kw
Installation Requirements : Front : 100cm
                                   Rear, Left side, Right side : 5cm
                                   Placement : Built-in wheels provide mobility(Option Cart)
Room Conditions : Use Environment : 10~40℃, 30~75%RH
                          Installation Environment : -20~60℃, 0~95%RH
Printer : Built-in Thermal Printer(Brief Mode / Detail Mode)
           Cycle Parameters(Temp, Pressure, Time, Daily&Total Cycle, etc)
Cart(Option) : 613×665×850(W×H×D)mm
 
* Total cycle time may vary depending on the conditions of the sterilization load such as
  instrument type, quantity, dryness and so on.



Consumables

● Sterilant Cartridges
   (Hydrogen Peroxide 50%)
   1 cartridge/cycle
● Packing
    Tyvek Pouch
    Non-Woven
    SheetImpulse Sealer
● Maintenance*
    Vacuum Oil
    Oil Mist Trap

*Recommend to be changed every 250 cycles. However, the number of cycles can vary according to daily practices of users in terms of sterilization loads(types, quantity, moisture content) and frequency of sterilization and etc.

● Sterilization Monitoring
    CI(Chemical Indicator) : to monitor if the sterilization loads are exposed to H2O2 by a color change.
    BI(Biological Indicator) : to monitor if the sterilization is successful by an incubation of bacillus.
● Exclusive Cart(Option)HPS-30 : 613×665×850(W×H×D)mm
 

TRAINING MANIKINSTRETCHER & SPLINTDEFIBRILLATOR▷ COVID-19MES : RestraintMES : Military equipmentMES : DMAT equipmentMES : Bags & Cases
CONTACT US

T. +82-42-256-2035
    +82-42-253-2034
F. 070-7614-2072

현재 브라우저에서는 지원하지 않는 사이트입니다. 아래의 다른 브라우저를 다운받아 사용해주세요.